1. Description
The Rosemount™ 5408 Non-Contacting Radar Level Transmitter uses enhanced technology and Human Centered Design to deliver accurate, reliable measurements on both liquid and solid materials. Using two-wire FMCW technology the Rosemount 5408 deploys a continuous echo to maximize radar signal strength and produce a more robust and reliable measurement. Delivering ease-of-use at every touch point, the Rosemount 5408 uses an intuitive software interface to guide the operator through installation, commissioning, proof-testing and maintenance. Safety certified to IEC 61508 for SIL 2 applications, the Rosemount 5408:SIS reduces the cost of risk, increases efficiency and protects people and the environment.
2. Specification
Accuracy: Standard: ± 0.08 in. (± 2 mm) Ultra accuracy: ± 0.04in. (± 1mm)
Measurement Range: 131 ft (40 m), 82 ft (25 m) for Rosemount 5408:SIS in Safety modeOperating Pressure1450 psi (100 bar)
Operating Temperature: -76 to +482 °F (-60 to +250 °C)
Power Supply: 4-20mA/HART: 12-42.4 VDC (12-30 VDC in Intrinsically Safe installations)
Foundation™ Fieldbus: 9-32 VDC (9-30 VDC in Intrinsically Safe installations and 9-17.5 VDC for FISCO)
Communication Protocol: 4-20mA HART® (2-wire loop-powered), Foundation™ Fieldbus
Certifications/Approvals: ATEX, IECEx, FM, CSA, 3-A, CRN, see full specs for complete list of certifications
Safety: IEC 61508 certified to SIL 2 TÜV tested and WHG approved for overfill prevention
Antenna type: Cone antenna, Process seal antenna, Parabolic antenna
3. Feature
- Low 12V dc lift-off voltage
- Immune to intermittent power loss
- Unique PTFE seal design eliminates the need for O-rings
- Model tailored to SIS requirements, certified to IEC 61508 SIL 2
- Solid measurement with a unique solids algorithm
- Process seal antenna for applications with heavy condensation and aggressive media. Also available with Tri Clamp connection.
- 3-A certified for hygienic applications
4. How to Order

Samson 3710 Reversing amplifier with pressure gauge double acting
Official Website Reversing amplifier to operate a double-acting pneumatic actuator using a single-acting pneumatic or electropneumatic positioner or limit switch
E+H RIA15 process indicator Loop-powered Ex ia process indicator as field or control panel device fo
RIA15 process indicator The process indicator is available with 4 to 20 mA or with HART® protocol. In the HART® version up to 4 measured values of one sensor can be indicated in alternation. For this, the indicator can be set as a primary or secondary HART® master and actively inquire the values from the sensor. The small voltage drop of < 1V (< 1.9 V with HART®) is a huge advantage, especially in Ex-applications, where in most cases only a reduced voltage is available.
Flowserve Pneumatic Actuators - Linear - VL Series VL25 Valtek
VL Actuator Valtek VL series spring cylinder linear actuators are powerful, compact, high-performance pneumatic actuators that provide solid throttling or on-off operation for automatic control valves. The positioner supplies air to both sides of the piston, providing stiff, precise movement and high-frequency response and quick stroke speeds.
Please use our online inquiry contact form below if you have any questions, our team will get back to you as soon as possible.